熙研生物科技
Your location:
Homepage
/
/
/
SVG reactive power compensation standard distribution prefabricated cabin
03
03
SVG reactive power compensation standard distribution prefabricated cabin
0.0 0.0
Product description

The application explains and analyzes the structure of the cabin. Below, we will combine the above categories with reality

1. Structural analysis of 10kV voltage prefabricated cabin

①. According to the compensated capacity, it can be divided into 5Mvar or less.

5Mvar prefabricated cabins mostly use a standard delivery size of 40 feet.

That is, 12200mm(L)x2440mm(W)x2890mm(H), the size can be slightly adjusted according to the actual application, the height adjustment range is relatively loose (between 100mm and 200mm), if the size adjustment is too large, it will greatly increase the transportation cost ( Consider traffic and road administration fines).

Depending on the application, there is also a smaller capacity SVG compensation device, and the standard delivery size is 20 feet.

Namely: 6058mm(L) x 2438mm(W) x 2591mm(H)

② The cabin is divided into three areas, separated by partitions:

SVG control room,

SVG compensation room,

SVG charging room,

1. SVG control room:

The control room is generally equipped with one or two intelligent control systems,

Distribution boxes, lights, heaters, thermostats, open-loop or closed-loop coolers,

The distribution box supplies power to the control system and the entire cabin's lighting, smoke alarms, heaters, and other equipment. The wires pass under the floor of the cabin and are hinged on the inspection cover.

The cabinet of the control system adopts the cable routing method under the floor, and sends the input and output signal lines of the control line to the SVG compensation room area through the cable channel under the floor. The control system cabinet adopts upper and lower fixed type to ensure that the bumps of the cabin body during transportation will not cause damage to the electrical components.

Since the control system cabinet is equipped with more sophisticated equipment, the control cabinet body needs to ensure the seismic strength and anti-shake strength required for transportation:

Since the control system cabinet is equipped with more sophisticated equipment, the control cabinet body needs to ensure the seismic strength and anti-shake strength required for transportation:

GB/T 2423.5-1995 "Impact Test"

GB/T 2423.10-2008 "Sine Vibration Test"

GJB 150.18-1986 "Impact Test of Military Equipment"

GB/T 19183.5-2..3 "Climate, mechanical test and safety requirements for outdoor enclosures"

We could not find any corresponding parameters, please add them to the properties table

更多产品

MNS type standard (economical) withdrawable low-voltage switchgear cabinet
Details
GCS type standard (economical) withdrawable low-voltage switchgear cabinet
Details
GCK type withdrawable low-voltage switchgear cabinet (KB profile frame)
Details
GGD type low voltage power distribution cabinet
Details

Liaoning guoyuan group

Add: anshan city in liaoning province economic development
zone I double Station Road 33

Service telephone:0412-8222682

Marketing:0412-8222301    Fax:0412-8222582

Technical:0412-8222081    Fax:0412-8222579

E-mail:lngyjt@lngyjt.cn

COPYRIGHT © 2020  Liaoning guoyuan group  ALL RIGHTS RESERVED. 

辽ICP备2020012890号-1  

Powered by: 300.cn  jinzhou.300.cn